Top Good quality CZPT AC Servo Brushless Reluctance CZPT Motor
Item Attribute
one.Suitable for the 6500rpm high velocity
2.Large electrical power & substantial torque
3.Higher performance
4.Small dimensions
5.Reduced noise reduced vibration
six.Patented cooling composition
7.Simple servicing and prolonged lifestyle time
eight.Efficient Coaxial Admirer
Technical specs
Design kind: SRPM205L8XF75
Voltage: 380V AC
Rated Electricity: 75KW
Rate Torque : 110N.m
Operating velocity: 6500rpm
Effectiveness: 96.5%
Services Aspect: one.2
Isolation: H/F
H2o/dust Evidence: IP54
Pole Quantity: 8
N Fat: 97KG
Cooling Strategy: Air
Position Signal: Resolver (optional)
Set up Strategy: B35
Software
Fans,Pumps,Compressors
Other motors you will be intrigued in
Motor variety | Voltage (V AC) |
Rated power (kW) |
Rated torque (N.m) | Rated pace (rpm) |
Efficiency (%) |
Support Issue | Insulation | Ingress safety | Pole Variety | Bodyweight (kg) |
Cooling Technique | Place Signal | Set up Strategy |
SRPM205L8XF18.five | 380 | 18.five | 35.3 | 5000 | ninety six | 1.2 | H/F | IP54 | eight | 38 | Air Cooling | Resolver | B35 |
SRPM205L8XF22 | 380 | 22 | 36.three | 5800 | 96 | one.two | H/F | IP54 | eight | 41 | Air Cooling | Resolver | B35 |
SRPM205L8XF30 | 380 | thirty | 49.4 | 5800 | 96.1 | 1.2 | H/F | IP54 | 8 | forty six | Air Cooling | Resolver | B35 |
SRPM205L8XF37 | 380 | 37 | 55 | 6500 | 96.three | 1.2 | H/F | IP54 | eight | 50 | Air Cooling | Resolver | B35 |
SRPM205L8XF45 | 380 | 45 | sixty six.one | 6500 | ninety six.3 | 1.2 | H/F | IP54 | eight | seventy six | Air Cooling | Resolver | B35 |
SRPM205L8XF55 | 380 | 55 | 80.8 | 6500 | 96.3 | 1.2 | H/F | IP54 | 8 | eighty five | Air Cooling | Resolver | B35 |
SRPM205L8XF75 | 380 | 75 | one hundred ten | 6500 | 96.five | one.two | H/F | IP54 | 8 | 97 | Air Cooling | Resolver | B35 |
SRPM314L8X135 | 380 | one hundred thirty five | 253 | 5100 | 97.5 | one.2 | H/F | — | eight | — | Refrigerant | Resolver | — |
FAQ
one. Can performanent magnet synchronous motor be used as generator?
No. Permanent magnet synchronous motor is definitely distinct from generator. It is only ac motor that outputs pace and torque to drive electric powered gadgets, but not power source.
2. Why can not immediately use 3 stage ac provide voltage to start long term magnet synchronous motor?
Becuase rotor is with massive innertia, and magetic documents spins so fast that static rotor has no way to spin with magetic submitted.
3. Any unique complex ask for on this motor’s VFD driver? And Do you have these kinds of driver?
Long term magnet synchronous motor’s driver should be vector control VFD with specific inner software program, these kinds of as Siemens 6SE70 sequence, Yakawa CR5 collection, ABB ACS800 collection, Mitsubishi A740 sequence, B&R P84 and P74 sequence, and so forth.. Sure, our MH300 series VFD matches with this motor.
4. Is there any protective measures to protect permanent magnet rotor from failure?
Sure, each and every long lasting magnet rotor passes corrossion resistance, consistency, substantial temperature demagnetization test, linear demagnetization check, and so on. Its demagnetization index is in 2%. But if functioning atmosphere is serious oxiditive corrosion, kindly advise for higher safety degree.
5. Where is this long term magnet synchronous motor usually utilized to?
This long lasting magnet synchronous motor is usually used to variable frequency velocity circumstance.